Now livetag icon
The official Gen AI Landscape report for 2026 is here. Don’t miss out!Get your copybanner icon

Analyse de l'application CI Select pour le 4 août

CI Select

CI Select

  • Mario Svirsky
  • App Store Apple
  • Gratuit
  • Médical
For cochlear implant users. Request manual at CISelect.questions@gmail.com or https://med.nyu.edu/research/translational-auditory-research-lab/sites/default/files/ci-select-manual.pdf NOTE: Instructions for users of Cochlear devices with 22 active electrodes and default frequency allocation table (188-7938Hz). Users with deactivated electrodes or non-default FAT should consult the manual. 1) Audio link to iPhone: • N7 processor or newer: Use MiniMic 2+ with audio cable between iPhone and Mini-Mic 2+ line-in jack. • N6 processor or older: Connect iPhone via audio cable to speech processor. • Deactivate microphone input by: o Using accessory-only map (consult audiologist) o Using remote to set 100% accessory/0% microphone mix ratio NOTE: Current version may not work well with Bluetooth connection between the iPhone and the speech processor. Use wired connection only. Using CI Select: • Adjust iPhone volume to comfortable level using speech or continuous audio. • Select grid boxes (each one represents a different FAT) to compare sound quality and speech intelligibility. Use "LF edge" slider or click boxes to change settings. Red square shows current setting. Default is 188Hz (standard FAT). • Note: Slight audio delay may occur. If bothersome, minimize acoustic input by removing acoustic component, hearing device in other ear, or using ear plug in opposite ear. • Test different FATs until finding best intelligibility and sound quality. App makes no permanent changes—share preferred settings with audiologist for permanent map changes. Grid Searching Tips: • Tried FATs appear lighter green. Current FAT is red. • Click "Save Favorite" to mark promising FATs (yellow). Select multiple favorites. • "Delete last" removes most recent favorite. Repeat to reset grid. Advanced Option - Extended Frequency Mode: Default grid adjusts LF edge only (sufficient for most users). For full control: • Click "Extended Frequency Mode" (EFM) below LF edge bar • This gives access to full grid with LF edges (rows) and HF edges (columns) • Selected box shows LF & HF intersection • Toggle EFM switch to return to default view For non-standard settings, reference the full manual for detailed instructions.
CI Select

Classement dans le store

Le classement des stores est basé sur plusieurs paramètres définis par Google et Apple.

Toutes les catégories dans
États-Unis--
Médical dans
États-Unis--
Créez un compte pour voir les téléchargements mensuels moyensContactez-nous

Statistiques de classement dans le temps pour CI Select

Classement d'utilisation et classement Apple App Store de Similarweb pour CI Select

Classement

Aucune donnée disponible

Ranking par pays pour CI Select

Pays dans lesquels CI Select est le mieux classé dans ses principales catégories

Aucune donnée à afficher

Principaux concurrents & apps alternatives

Applications ayant une forte probabilité d'être utilisées par les mêmes utilisateurs, à partir du même store.

CIQOL

CIQOL

The Medical University of South Carolina

Cochlear Implant Care App

Cochlear Implant Care App

Children's Research Institute

HearCare

HearCare

MED-EL Elektromedizinische Geraete GmbH

Clearly Audiobooks

Clearly Audiobooks

BioSpeech, Inc.

CI Select VS.

août 4, 2026