DART SimVent 앱 분석 (11월 20일)
DART SimVent
- Erik DeAnda
- Apple App Store
- 유료
- 의료
Turn an iPad into a realistic mechanical ventilator for simulation training. The learner sets the ventilator; the instructor changes the patient from a panel the learner never sees. From the team behind DART Sim.
WHAT THE LEARNER SEES
• A modern touchscreen ventilator. Mode badge, message bar, monitored values down the left (Ppeak, ExpMinVol, VTE, fTotal, SpO2), three live waveforms and round controls down the right, exactly as on a current transport/ICU ventilator.
• Volume and pressure modes. (S)CMV+, PCV+, SIMV+, PSIMV+ and SPONT with apnea backup. Controls for Vt, Rate, PEEP/CPAP, Oxygen, Ti or I:E, Psupport, ETS, flow trigger, pressure ramp and Plimit. Touch a control to select it, touch again to adjust, Confirm. Changes apply at the next breath, like the real device.
• Waveforms that respond to the patient. Pressure, flow and volume vs time, plus plethysmogram and CO2 waveform from the built-in SpO2 and CO2 sensors. Pressure-volume, pressure-flow and volume-flow loops. One-hour trends.
• Dynamic Lung. An animated lung that inflates with each breath, stiffens with low compliance and narrows its airways with high resistance, with PetCO2, SpO2 and pulse alongside.
• Alarms that behave like the device. High and medium priority tones, Pressure high, Pressure limitation, low and high minute volume, tidal volume, rate, Apnea and Disconnection, SpO2 and PetCO2 limits. Alarm limits window, two-minute audio pause, alarm buffer.
• Soft keys from the real ventilator. O2 enrichment, manual breath and inspiratory hold, screen lock, suctioning tool. Monitoring window with Pplat, Pmean, Cstat, Rinsp, RCexp and leak. Events log of every setting change and alarm.
WHAT THE INSTRUCTOR CONTROLS
• Hidden patient panel. Compliance, resistance, spontaneous rate and effort, circuit leak, disconnection, SpO2, pulse and PetCO2. Every change shows up on the traces and the alarms within a breath.
• Nine one-tap scenarios. Normal adult, ARDS, COPD and bronchospasm, obstructed tube, circuit leak, disconnection, weaning, agitated patient with asynchrony, apnea.
• Scenario editor. Build your own cases as a spreadsheet: one row per step with a duration and the patient values that apply. Pin a saved scenario as a chip, run it, and step through it with Prev, Stop and Next keys that sit on the ventilator's top bar.
MADE FOR THE CLASSROOM
• Stands alone. No account, no subscription, no internet connection. Built-in SpO2 and CO2 sensors, so the whole picture is on one iPad.
• In your language. English and Spanish, with the terms used on Spanish-market equipment.
• Built for the iPad in landscape, on the 10.2-inch iPad and up.
DART SimVent is a training tool. It is not a medical device and must never be connected to a patient.
스토어 순위
스토어 순위는 Google과 Apple이 설정한 여러 매개변수를 기반으로 합니다.
모든 카테고리 ·
브라질--
의료 ·
브라질--
월평균 다운로드를 확인하려면 계정을 만드세요문의하기
DART SimVent 순위 통계 추이
DART SimVent의 Similarweb 사용량 순위 및 Apple App Store 순위
순위
데이터가 없습니다
DART SimVent 국가별 순위
DART SimVent의 주요 카테고리 순위가 가장 높은 국가입니다
표시할 데이터 없음
주요 경쟁 앱 및 대체 앱
같은 스토어에서 동일한 사용자가 사용할 가능성이 높은 앱입니다.
표시할 데이터 없음
11월 20, 2026